Caribbean Disaster Mitigation Project
Implemented by the Organization of American States
Unit of Sustainable Development and Environment
for the USAID Office of Foreign Disaster Assistance and the Caribbean Regional Program

USAID Logo OAS Logo


Final Report: Kingston Metropolitan Area Seismic Hazard Assessment
Chapter 4: Site Response in the Kingston Metropolitan Area


Chapter 1 Chapter 2 Chapter 3 Chapter 4 Chapter 5
Bibliography Appendix 1 Appendix 2 Appendix 3

Figure 4.0 The Giddy House, as it is known today, was built in 1890 as the artillery store of the Victoria and Albert Battery in Port Royal. The Giddy House was tilted to its present day angle by ground failure and liquefaction during the 1907 Kingston earthquake (photo by M. Wiggins-Grandison, 1998).


4.0 Site Response in the Kingston Metropolitan Area

Geologic conditions at or near a site have been known to influence the intensity of ground shaking from earthquakes for more than a century. Reid (1910) found that ground accelerations during the 1906 San Francisco CA earthquake on made-ground were up to twelve times those on solid rock. Observations of damage following earthquakes in California, Japan, Mexico, Venezuela, and Armenia (Borcherdt et al., 1989; Gutenberg, 1956, 1957; Rogers et al., 1985) consistently demonstrate the importance of local site conditions during earthquakes.

Only within the last 30 years have scientists and engineers been able to quantitatively describe these effects and develop methods to mitigate against earthquake-induced ground failure. The successes achieved by including these types of effects in building designs, codes, land use planning and other policy decisions, however, need to be tempered with the need for 'real-world' testing during actual earthquakes. Most of the serious damage sustained to large commercial and industrial facilities and infrastructure during the 1995 Kobe, Japan earthquake for example, occurred in areas of soft soil and reclaimed land. The worst damage occurred along the waterfront due to severe ground failure, liquefaction, lateral spreading and settlement (EQE, 1995).

Observations of both the 1692 Port Royal and 1907 Kingston earthquakes attribute the significant levels of ground motion and ground failure to local site conditions around Kingston Harbor (Brown, 1907; Fuller, 1907; Davison, 1907; Spencer, 1907; Cornish, 1908; Taber, 1920). The susceptibility of this region to ground failure is further underscored by the relatively moderate magnitude of the 1907 earthquake (M 6-6.5).

The Geological Survey Division of the Ministry of Mining and Energy compiled a site response map for Jamaica in 1984 (see Figure 4.1). One of the goals of the KMA Seismic Hazards Assessment is to better document site dependent effects and map the variation of site response within the Kingston Metropolitan Area at a finer scale than the Geological Survey Division map. Even at this scale, the analysis in this report only provides a regional approximation. Site specific analysis is still required to determine the ground response for individual projects.

In this section, we present five separate but interrelated investigations of site response for the Kingston Metropolitan area

Figure 4.1 Site response map for Jamaica compiled some 15 years ago by the Geological Survey Division.

These data are combined to produce a composite map of site response throughout the Kingston Metropolitan area. This site response map is then used to modify the 'hard rock' ground motions in Section 3 to develop a more realistic description of earthquake ground motions throughout the Kingston Metropolitan area.

4.1 Historic Ground Failure and Liquefaction

Liquefaction is the result of loose, water-saturated sand being shaken during an earthquake and assuming a semi-liquid state. Guidelines for the identification of liquefiable deposits and their susceptibility are summarized in CDMG Special Publication 117 (1997) and Werner (1998). In lieu of geotechnical investigations, however, observations of liquefaction during prior earthquakes can be used to identify areas that may fail again in future earthquakes. Field studies following past earthquakes indicate that liquefaction tends to recur at many sites during successive earthquakes (Youd, 1984). Zones that experienced ground failure and liquefaction during the 1906 San Francisco, California earthquake also failed during the 1989 Loma Prieta earthquake (Benuska, 1990).

Descriptions of ground failure and liquefaction in the 1692 and 1907 earthquakes were collected during Phase One and mapped on a common base (see Figure 4.2). In general, the coastal zone in the St. Andrew and Kingston parishes that experienced the greatest ground failures were affected by liquefaction, fissuring, slumping, and differential settling. Here soils are composed of the Liguanea Formation and the water table is close to the surface.

Figure 4.2 Areas of liquefaction during the 1907 Kingston earthquake.

Following the 1907 earthquake, Brown (1907) mapped a zone of fissuring and subsidence 100 to 300 yards wide, which starting in the western part of Kingston, ran along the waterfront encircling the harbor and continued along the Palisadoes (see Figures 2.2 and 4.2). Soundings within the harbor revealed that the bottom had sunk in places around the edge of the harbor by 4 to 5 fathoms [24 to 30 feet].

The Palisadoes peninsula from Harbor Head to Port Royal - suffered extensive liquefaction and differential settling. Levels of ground shaking were so severe that surface waves were noted in Port Royal during the earthquake. Zones of ground failure also extended east of the Palisadoes, from Harbor Head to Bull Bay where soils consist of loosely consolidated coarse sands and gravels. Extrusion of sand/water near was noted at Victoria Market and along the Palisadoes (Fuller, 1907 p. 709). Increased flow was noted in a spring at Rockfort. This same spring flooded the road after the 1993 Woodford earthquake.

4.2 Engineered and Non-Engineered Ground

Damage in the Marina District in San Francisco, California during the 1989 Loma Prieta earthquake was strongly influenced by the location of artificial fill and construction rubble (Benuska, 1990). Areas of San Francisco Bay, such as Foster City and Redwood Shores, that were constructed on stabilized fills using appropriate geotechnical engineering techniques, performed better and had no appreciable liquefaction effects.

Reclaimed land is typically classified as being either engineered or non-engineered. Engineered ground consists of specially selected and prepared materials that are carefully deposited and compacted on site. Deposits are then tested to determine their load bearing strength. Non-engineered ground, on the other hand, consists of loose, uncompacted sands, fill, and construction rubble that have not been deposited in any systematic fashion. Both types of ground are identified as categories for special consideration in the National Earthquake Hazard Reduction Program (NEHRP) site classifications discussed in the next section.

Figure 4.3 shows the distribution of reclaimed land in the Kingston Metropolitan area. Areas of engineered and non-engineered fill are differentiated. The data used to construct Figure 4.3 were provided by the Urban Development Corporation (UDC), who are responsible for the redevelopment of the Kingston Waterfront in the Kingston Metropolitan Area, and from soil investigation reports from local geotechnical companies. Some of these soil reports date to the early 1950's. In general, the boundary between engineered and non-engineered fill approximates the old (pre-1950) coastline around Kingston Harbor.

The Kingston Waterfront re-development is mainly on engineered fill and contains many of the largest building structures, important industrial, harbor and warehouse facilities in the Kingston Metropolitan area. These include the Urban Development Corporation building, the Petrojam Oil Refinery, Newport West and New Port East harbor and warehouse facilities, the Bank of Jamaica building and Scotia Bank Center. Other important developments on engineered fill outside the Kingston Waterfront Redevelopment area include the Norman Manley International Airport at Palisadoes, the Portmore-Kingston Causeway and Portmore Housing Development in St. Catherine.

Engineered fill is composed of 2.4 to 7 meters of thick hydraulic fill consisting of fine to medium sand and gravel with a trace of shell fragments. The fill was engineered using ground improvement methods such as conventional compaction and surcharge. Periodic borehole and probe tests were done to determine the final bearing strength of the hydraulic fill for design and construction. Soil conditions underlying the engineered fill consist of from 1.5 to 6 meters of organic silt, fine sand and varying proportions of decayed vegetation (soft, compressible soil).

As seen in Figure 4.3, areas with significant concentrations of non-engineered fill are located in the western part of Kingston, south of Spanish Town Road. Here the composition is more variable and generally consists of from 1 to 3 meters of loose to uncompacted sands, gravel, construction rubble (brick and concrete), organic material, and cinder/ash. Soils underlying the non-engineered fill ranges from highly compressible organic silt and loose fine sand, soft clayey soil, marl and limestone chips. Standard geological criteria are of little use in characterizing soils within these fills, which are less homogeneous than natural deposits. There is no reason to assume lateral stratification in these fills and the validity of extrapolating subsurface data is questionable.

Figure 4.3 Location of areas of engineered (green) and non-engineered (red) fill in the Kingston Metropolitan area.

4.3 Site Classifications Based on Well Data

The Liguanea Plain is a Holocene gravel fan which was formed by sedimentation from the Hope River before the river was diverted to its present channel (Ahmad and Robinson, 1994). It incorporates a sequence of poorly sorted sands and gravels interbedded with sands and clays. The top 8 meters of fan sediments have been identified by Ahmad and Robinson (1994) as old debris flow deposits, characterized by very large boulders of andesite and conglomerate. Sources for the debris flows were ancient landslides, which originated in the catchment of the Hope River, and flowed westward along paleodrainage channels. Sediments that post-date the Liguanea gravels include fanglomerate and colluvium deposits along much of the mountain front in the Kingston area and river terraces, colluvium and flood plain deposits associated with the Hope River and its tributaries. The present day fan surface slopes southward towards Kingston Harbor. Farther west, mangrove and salina deposits dominate the Hunts Bay area.

Well logs from 12 water wells drilled during 1977-1978 were used to determine soil profile types for the Liguanea Plain and are summarized in Figure 4.4. The complete logs are included in Appendix 2. The soil profiles are determined using the parameters defined by both the Structural Engineers Association of California (SEAOC, 1996) and the U.S. National Earthquake Hazards Reduction Program Recommended Provisions (NEHRP, 1997). Both classification schemes are based on geotechnical information, such as shear wave velocities, and Standard Penetration Resistance tests. Shear wave velocities are either directly measured using geophysical techniques, extrapolation of local data from the same geologic units, or estimated using established correlations from other geotechnical properties (e.g. Standard Penetration Test (SPT) and Cone Penetration Test (CPT) penetration resistance [see ASTM D 1536-84], void ratio, undrained shear strength [see ASTM D 2166-91 and ASTM D2850-87]) for each site. The water well logs summarized in Figure 4.4 did not contain these types of geotechnical information, so we used geologic analogs from investigations in the Los Angeles, CA area to help constrain the soil classifications (Fumal and Tinsley, 1985; Rogers et al., 1985).

Figure 4.4 Well logs from 12 water wells drilled in the Liguanea Plain during 1977-1978. The first 100 feet are summarized in this figure. Complete logs are available in Appendix 2.

SEAOC Site Classification

The latest revision of the Jamaican Building Code recommends the use of the Caribbean Uniform Building Code (CUBIC) format for earthquake loads and adjusted the design philosophy to conform to the SEAOC code. Site coefficients or response factors, S, are assigned based on the soil profile. Table 4.1 lists the 1996 SEAOC coefficients and their descriptions. Soil profile, S3 is recommended by SEAOC in locations where soil properties are not known in sufficient detail to determine the soil profile type.

Table 4.1 1996 SEAOC site coefficients

Type

Description

Coefficient value

S1

A soil profile with either:
  1. A rock-like material characterized by a shear wave velocity greater than 2,500 feet per second (762 m s-1), or by other suitable means of classification
  2. or
  3. Medium stiff to stiff or medium dense to dense soil conditions where the soil depth is less than 200 feet (61 m).

1.0

S2

A soil profile when predominately medium dense to dense or medium stiff to stiff soil conditions, where soil depth exceeds 200 feet (61 m)

1.2

S3

A soil profile containing more than 20 feet of soft to medium stiff clay but not more than 40 feet of soft clay

1.5

S4

A soil profile characterized by a shear wave velocity of less than 500 feet per second, and containing more than 40 feet of soft clay.

2.0

NEHRP Site Classification

Another site classification scheme, developed by the U.S. National Earthquake Hazards Reduction Program Recommended Provisions (NEHRP, 1997) is shown in Table 4.2. Site classes are determined by obtaining an average shear wave velocity for the upper 30 m (100 feet) of soil. Soil profile D is recommended for areas lacking geotechnical information.

Table 4.2 1997 NEHRP Site Classifications

Soil Profile Type

Description

Shear Wave Velocity
(m s-1)

Standard Penetration Resistance
(blows/30 cm)

Undrained Shear Strength (kPa)

A

Hard rock

>1,524

n/a

n/a

B

Rock

762 to1,524

n/a

n/a

C

Very dense soil and soft rock

366 to 762

> 50

>96

D

Stiff soil

183 to 366

15 to 50

48 to 96

E

Soil profile with Vs <183 m/s, or any profile with more than 3 m of soft clay defined as soil with plasticity index > 20, water content >40%, and undrained shear strength <24 kPa.

F

Soils requiring site-specific evaluation – including liquefiable soils, and peats or organic clays with thickness > 3 m

The maximum considered earthquake spectral response for short periods (SMS) and 1 second period (SM1), adjusted for site effects, is determined by multiplying the site coefficients in Table 4.3 and 4.4 by the respective levels of ground motion, SS and S1, respectively.

SMS = FaSS

SM1 = FaS1

These values are shown in Tables 4.5 for short period motions and Table 4.6 for long period (1 second) motions. Values appropriate for the Kingston Metropolitan area have been highlighted and range from 0.24 to 0.44, based on 10% probability of exceedence in 50 years on bedrock.

Experience has shown that low peak ground accelerations of 0.05 to 0.1g are amplified by factors of 1.5 to 4 at sites containing soft clay layers and depths to bedrock of several hundred feet. Average amplification for soft soil sites tend to decrease as the rock acceleration increases, from 2.5 to 3 at low accelerations to about 1.0 at rock accelerations of 0.4 g. This effect is directly related to the non-linear stress-strain behavior in soil as levels of acceleration increase.

Table 4.3 Site coefficient, Fa , as a function of soil profile type and short-period peak spectral acceleration, Ss

Soil Profile

Type

Peak Acceleration

Ss < 0.25

SSs = 0.5

SSs = 0.75

SSs = 1.00

SSs > 1.25

A

0.8

0.8

0.8

0.8

0.8

B

1.0

1.0

1.0

1.0

1.0

C

1.2

1.2

1.1

1.0

1.0

D

1.6

1.4

1.2

1.1

1.0

E

2.5

1.7

1.2

0.9

*

F

*

*

*

*

*

Ss is the maximum considered earthquake, 5% damped, spectral response acceleration at short periods. * need to perform site-specific geotechnical analysis and dynamic site response analysis

Table 4.4 Site coefficient, Fv , as a function of soil profile type and 1 second period peak spectral acceleration, S1

Soil Profile

Type

Peak Acceleration

S1 < 0.1

S1 = 0.2

S1 = 0.3

S1 = 0.4

S1 > 0.5

A

0.8

0.8

0.8

0.8

0.8

B

1.0

1.0

1.0

1.0

1.0

C

1.7

1.6

1.5

1.4

1.3

D

2.4

2.0

1.8

1.6

1.5

E

3.5

3.2

2.8

2.4

*

F

*

*

*

*

*

S1 is the maximum considered earthquake, 5% damped, spectral response acceleration at 1 second period. * need to perform site-specific geotechnical analysis and dynamic site response analysis bold-italics illustrate range of Fa values estimated for the Liguanea Plain

Table 4.5 Maximum considered short period spectral response, SMS, a function of soil profile type and short-period acceleration, SS

Soil Profile

Type

Peak Acceleration

Ss < 0.25

Ss = 0.50

Ss = 0.75

Ss = 1.0

Ss > 1.25

A

0.20

0.40

0.60

0.80

1.00

B

0.25

0.50

0.75

1.00

1.25

C

0.30

0.60

0.83

1.00

1.25

D

0.40

0.70

0.90

1.10

1.25

E

0.62

0.85

0.90

0.90

*

F

*

*

*

*

*

* - need to perform site-specific geotechnical analysis and dynamic site response analysis

Table 4.6 Maximum considered 1 second spectral response, SM1, a function of soil profile type and 1 second period acceleration, S1

Soil Profile

Type

Peak Acceleration

Aa < 0.1

Aa = 0.2

Aa = 0.3

Aa = 0.4

Aa > 0.5

A

0.08

0.16

0.24

0.32

0.40

B

0.10

0.20

0.30

0.40

0.50

C

0.17

0.32

0.45

0.56

0.65

D

0.24

0.40

0.54

0.64

0.75

E

0.35

0.64

0.84

0.96

*

F

*

*

*

*

*

* - need to perform site-specific geotechnical analysis and dynamic site response analysis bold-italics illustrate range of Ca values estimated for the Liguanea Plain

4.4 Depth to Basement

Both the amplitude and duration of strong ground shaking are dependent on the thickness of the alluvium. Sites with thin alluvium tend to amplify over a narrow frequency range, while sites with thick alluvium amplify shaking over a broader range of frequencies. Variations in the thickness of Quaternary sediments in Los Angeles have been shown to produce factor of 5 variations in the spectral ratio of the horizontal component of ground motion, in the depth range 10-400 m for intermediate periods (affecting 5 to 30 story buildings) (Rogers et al., 1985). A rule of thumb for the fundamental period, T, of a multistory buildings is T = 0.1 s per story. In other words, a 20 story building would have a fundamental period of 2 seconds. For periods less than 0.5 s, the most significant factors controlling ground response are mean void ratio in the near-surface layers, the unconsolidated (Holocene) sediment thickness and depth to basement rock. For periods greater than 0.5 s, depth to basement and the thickness of Quaternary sediments were found to be controlling factors. These differences highlight the need for site-specific evaluation.

The predominant period of the soil deposit can be estimated (assuming vertically propagating waves in a linear elastic soil media) from the relationship

T = 4H/Vs

where H is the thickness of the deposit and Vs is the average shear wave velocity of the soil.

The depth to basement (in this study defined as Miocene limestone) or the thickness of the Liguanea alluvium is largely unknown. Well hole data (summarized in Appendix 2) indicate that of the 199 wells drilled, depth information was recovered for only 44 wells and only seven wells actually hit Miocene Limestone. A number of 200 m wells drilled for the Water Authority were useful in setting minimum depths to basement.

Estimates of the depth to basement were also determined using gravity measurements (see Appendix 3). Two-dimensional models generated from the gravity data were consistent with a north-south variation of alluvium thickness from less than 100 m near Constant Spring to approximately 500-600 m near Kingston Harbor. These values are also consistent with estimates from a simplified depth of overburden calculation (500 to 700m). From east to west along Old Hope Road and Washington Boulevard, the thickness of Liguanea alluvium ranges from 300 to 400 m with less variation.

We were not able to recover shear wave velocity measurements for the Liguanea plain. Instead, we rely on geologic analogs. Los Angeles, California has a geologic setting similar to the Kingston Metropolitan area - alluvial fan and river flood plain deposits. For the Liguanea Plain, we estimate the average shear wave velocity to be 320- 495 m s-1 range based on geologic parallels with measured parameters in the Los Angeles basin (Fumal and Tinsley, 1985). These values are consistent with the values for C/D soils in the NEHRP Site Classifications (366 to 762 m s-1, see Table 4.2).

Based on these parameters, H = 200 -700 m and shear wave velocities for type C soils in Table 4.2 (V = 366 to 762 m s-1), the fundamental periods, T, varies by a factor of two to three throughout the Kingston Metropolitan area (from approximately 1 to 2 sec for 200 - 300 m thick alluvium beneath Halfway Tree and New Kingston to longer periods, > 4 sec, at Kingston Harbor).

4.5 One- Dimensional Wave Propagation Models (SHAKE21)

While the simple relationships developed in Section 4.5 provide guidance as to the period range at which site effects may be significant, they do not address the magnitude of the amplification of the ground motions. The NEHRP tables (Tables 4.1-3) provide general guidance and suggest that ground amplification is an important factor at the levels of acceleration expected for the KMA. More detailed analysis, however, requires information about the thickness and stiffness of soils and underlying rock, and the strain dependent properties of the soils themselves.

Aspinall and Shepherd (1977) modeled soil response for KMA using the computer program SHAKE (Schnabel, Lysmer and Seed, 1972) and generalized models of the Liguanea Plain. The ground motion estimates used as inputs into the model were for sources of varying magnitude and distance and ranged from M 7.5 at 160 km, to M 7.0 at 80 km, to M 6.0 at 50 km. This is motivated by Shepherd's (1971) conclusions that the majority of large earthquakes affecting Jamaica occurred off the north coast of the island. At that time there was a lack of detailed information about the depth to basement and subsurface lithology of the Liguanea Plain. Depths that were considered in their analysis ranged from shallow to approximately 350 meters and representative soil profiles were used that consisted of sand and clay layers at shallow depths (<50m) and all clay at depths greater than 50m.

We have updated the earlier Aspinall and Shepherd (1977) SHAKE study by

We use SHAKE21 to estimate ground response at a number of sites throughout the KMA - Elleston Flats, National Heroes Circle, and Buttercup Park. SHAKE21 (Kagawa, 1995) was written for Windows95/NT environment and is based on equivalent linear dynamic soil response method that computes the response of a horizontally layered visco-elastic system subject to vertically propagating shear waves. It computes strain-compatible shear moduli and damping ratios assuming an effective to peak strain ratio of 0.65, for all soil layers except the half space (which represents the hard rock basement).

SHAKE-type analyses are used in engineering practice and have been demonstrated to provide accurate results in situations where the ics represents non-strain compatible result.

Frequency (Hz.)

Well Site

0.5

1

10

30

Elleston Flats

2.2

1.5

0.67

1

Buttercup Park

0.9

0.7

1.7